Replaces Theimer THS2030, Ushio MHL15, Heraeus Q2127Z11, Amba AM571X, Sylvania M038, Juhnast JGMHO 2030-0, Beltron 25054 lamps.
Wattage: from 1920W to 6000W
Lamp:
- Single-walled metal halide UV heater with lead and gallium additives
Features:
- Optimized spectrum for UV-A radiation
- HPM Repro lamps radiate in the diazo range
- No ozone production
- Most lamps are designed to operate at different power levels, i.e., standby, mid-power, and full power
- Horizontal burner position +/-10°
Applications:
- Contact copying processes for images from transparent films onto UV-sensitive substrates, offset plates, printed circuits, or Microfilms
- UV curing of glues, resins, and colored varnishes
Lighting:
- Measures must be taken to protect eyes and skin from UV-B and UV-C radiation, which is also present in the spectrum.
- The bulb temperature must be maintained between 750 and 950°C, with a maximum of 350°C at the pinch points; this requires forced air cooling appropriate to the power level.
2-Wire Igniter PHI915481
-
-Z1 - FAMILYLampes
-
-Z4 - PlusUsage spécial
-
-Z4 - TechnologyDécharge
-
Power supplyBallast Ferromagnétique CCG
-
Arc132
-
Energy efficience labelG
-
BaseC14X
-
Diameter35
-
Average nominal lifespan750
-
ManufacturerDR FISCHER
-
DimmableNon
-
Current9
-
Overall lenght205
-
Burning positionP 10
-
Power1950
-
Input voltage245
-
indice stockage
-
packing height18.5
-
packing width20
-
packing weight1.2
-
packing qte4
-
delai sur commande10
-
packing longueur43
-
ecotaxe0.15
-
pcb1
-
Weight0.29
-
text_informationtxt_danger_uvc
-
statutActif - En cours d'existence
(à modifier dans le module "Réassurance")
(à modifier dans le module "Réassurance")
(à modifier dans le module "Réassurance")